Liaptsis, GeorgiosandLiaptsis, DimosthenisandCharlton, Peter(2015)Directivity Investigation of two Annular Phased Array Transducers.The e-Journal of NDT, 20 (4). ISSN 1435-4934
|
Text 103_Charlton_Rev1.pdf- Published Version Available under LicenseCreative Commons Attribution Non-commercial No Derivatives. Download (1MB)|Preview |
Abstract
环形相控阵换能器are well known in the medical field, with their main use being in ophthalmology and dermatology, and have started to be employed in the NDT industry relatively recently. Annular arrays consist of a centre circular element and multiple ring-shaped elements of different width. This unique geometry of the probe makes it difficult to determine the generating beam of the probe. For this reason, it was decided to produce directivity plots for individual elements for both probe configurations. The directivity plots were produced both experimentally and computationally. The generating knowledge of these plots will be novel for annular arrays since no previous work has been reported in the NDT industry.
Item Type: | Article |
---|---|
Uncontrolled Keywords: | 环形相控阵换能器 |
Subjects: | Q Science > QC Physics T Technology > T Technology (General) T Technology > TA Engineering (General). Civil engineering (General) T Technology > TJ Mechanical engineering and machinery T Technology > TK Electrical engineering. Electronics Nuclear engineering |
Divisions: | Institutes and Academies > Wales Institute for Science & Art (WISA) > Academic Discipline: Engineering |
Depositing User: | Professor Peter Charlton |
Date Deposited: | 18 Jan 2017 14:49 |
Last Modified: | 03 Jan 2023 13:38 |
URI: | https://repository.www.guaguababy.com/id/eprint/681 |
Actions (login required)
![]() |